EDON Corporation
Architectural Fiberglass
Fiberglass Fire Rating
FLAME RETARDENT RESINS, Class 1. Offers a wide variety of flame retardent properties. Engineered specifically
for building products and a myriad of other interior and exterior applications. Meets the most exacting requirements of local fire codes, IBC, DOT and
other government specifications.
TYPICAL PHYSICAL PROPERTIES |
|
|
Properties |
1/8" Unfilled Casting |
1/8" Glass Laminate |
Flexural Strength, psi 77° F |
16,000 |
30,000 |
Flexural Modulus, psi x 106, 77° F |
0.48 |
1.3 |
Tensile Strength, psi 77° F |
8,700 |
18,000 |
Elongation, % |
2.2 |
- |
Barcol Hardness |
45 |
50-55 |
Glass Content, % |
- |
29.8 |
FLAMMABILITY PROPERTIES |
(1/8" Glass Laminate) |
ASTME-84 (tunnel test) Flame spread.............................................................less than 25 (unfilled) |
smoke density.............................................................less than 380 (unfilled) |
HLT-15 Rating.........................................................................................100 |
ASTM D-635-74.......................................................................................AEB<1.0 CM |
ATB<5 sec. |
ASTM D-2863-74 (Oxygen Index)..................................................................36.5 |
Materials having a structural base of noncombustible material as determined in accordance with section 703.4.1 with a surfacing not more than 0.125 inch (3.18mm) thick that has a
flame spread index not greater than 50 when tested in accordance with ASTM E 84 shall be acceptable as noncombustible materials.
|